Abstract
Coal fire is a global catastrophe. Xinjiang suffers the most severe coal fire in China and even in the world. Coal firefighting work has been being conducted for decades in Xinjiang. In this paper, coal fire detection, extinguishing, and monitoring approaches that were derived from coal firefighting experience are introduced in detail by taking the Fifth Fire Area (FFA) of the Heshituoluogai coal fire for instance. We first introduce the geology and fire situation in the FFA. Before developing efficient strategies to extinguish it, magnetic and self-potential methods are adopted to delineate the extent of the fire. A composite index is proposed to better indicate the fire. The comprehensive coal firefighting method is illustrated in detail, which consists of surface cooling, excavation and leveling, borehole drilling, borehole water injection and grouting, and loess backfill. The subsequent temperature and CO monitoring records show that the fire is extinguished successfully without burnback. The methodology presented here provides guidance and reference for putting out other coal fires around the world.