Αναζήτηση αυτού του ιστολογίου

Τετάρτη 28 Δεκεμβρίου 2022

Clinical reproducibility of different centric relation recording techniques in edentulous individuals: an observational cross sectional study

alexandrossfakianakis shared this article with you from Inoreader

Abstract

Purpose

To assess the reproducibility of four different centric relation (CR) recording techniques, and time spent performing each technique in edentulous individuals.

Materials and Methods

Four techniques were assessed: extraoral gothic arch tracing (EOGA), intraoral gothic arch tracing (IOGA), deglutition (D), and frontal manipulation with tongue elevation (FMTE). Twelve subjects participated in the study; four technique records were performed on each volunteer by the same operator. Each record was repeated three times, in the same period of the day, with a 30 min interval between each technique. The reproducibility of each technique was assessed by the tri-dimensional displacement of the position of the condylar housing (mandible condyle) to the wall of the condylar guide (glenoid cavity) in the semi-adjustable articulator (anteroposterior, mediolateral, and superior-inferior). The time spent on each technique was timed in seconds (from the beginning of each technique until the wax occlusion fixation). The analysis of variance and the Tukey test were performed for anteroposterior displacement (two-way) and for time spent on CT recording techniques (one-way) (α &l t; 0.05). Regarding mediolateral and superior-inferior displacements, the non-parametric Kruskal-Wallis was performed for the comparison between recording methods, while the Mann-Whitney test was performed for the comparison between sides (α < 0.05).

Results

The factor recording technique interfered with the anteroposterior displacement (ANOVA: α < 0.001; F = 11.396). The technique D (right side: 3.78 ± 0.69 mm; left side: 3.45 ± 0.74 mm) showed a statistically significant difference compared to the other techniques (EOGA: right side: 3.00 ± 0.00 mm; left side: 3.00 ± 0.00 mm; FMTE: right side: 2.81 ± 0.52 mm; left side: 2.82 ± 0.79 mm; IOGA: right side: 2.90 ± 0.65 mm; left side: 3.12 ± 0.44 mm). The time spent on the recording technique influenced the results (ANOVA: α < 0.001; F = 21.118). The IOGA (340.40 ± 163.41 seconds) and EOGA (285.93 ± 133.84 seconds) required more time compared to the D (86.00 ± 34.33 seconds) and FMTE (101.33 ± 36.72 seconds) techniques.

Conclusion

Graphic recordings showed better reproducibility and accuracy of the position of the centric relation.

This article is protected by copyright. All rights reserved

View on Web

Esthetic and clinical outcomes after immediate placement and restoration: Comparison of two implant systems in the anterior maxilla—A cross‐sectional study

alexandrossfakianakis shared this article with you from Inoreader

Abstract

Aim

To assess the esthetic and clinical performance of a novel self-tapping implant system for single-tooth restorations in the esthetic zone after immediate placement and provisionalization.

Materials and Methods

This cross-sectional study included 52 patients contributing a total of 52 immediately placed and restored implants with ≥12 months after functional loading, comparing two different implant systems: Straumann® BLX (Institut Straumann AG, Basel, Switzerland; 25 patients) and Ankylos® (Dentsply Sirona, Hanau, Germany; 27 patients). As the primary outcome measure, peri-implant tissue esthetics were assessed by means of pink esthetics score (PES) rated by three independent clinicians. Moreover, as secondary outcome measures, the peri-implant tissue health was assessed by means of bleeding on probing, probing depth, and suppuration. Apart from that, the modified plaque index, keratinized mucosa width, and the presence of mucosal recessions were also assessed. When clinical signs suggested the possibility of peri-implantitis, radiographs were indicated to assess progressive bone loss.

Results

The mean PES ratings were 12.10 ± 1.10 for Ankylos versus 11.2 ± 1.86 for BLX, both achieving good esthetic results without significant differences (p = 0.143). There were no differences among most clinical parameters (plaque, bleeding on probing, probing depth, peri-implant mucosal recession), although peri-implant mucositis was present in one-third of the cases. The inter-rater agreement on esthetics was not significant (p < 0.250).

Conclusion

Within the limitations of the present study, it was concluded that the use of either BLX or Ankylos implant systems was associated to comparable peri-implant health and good pink esthetic outcomes during immediate implantation and restoration protocols, for at least 12 months.

View on Web