Αναζήτηση αυτού του ιστολογίου

Παρασκευή 9 Φεβρουαρίου 2018

Coronary CT angiography in patients with atrial fibrillation: Standard-dose and low-dose imaging with a high-resolution whole-heart CT scanner

Abstract

Objective

To compare image quality, observer confidence, radiation exposure in the standard-dose (SD-CCTA) and low-dose (LD-CCTA) protocols of coronary CT angiography (CCTA) in patients with atrial fibrillation (AF).

Material and methods

CCTA was performed in 303 patients using a CT scanner with 16-cm coverage (111 scans during sinus rhythm (SR); 192 during AF). LD-CCTA was used in 218 patients; SD-CCTA in 85 patients suspected of having coronary artery disease (CAD). Image quality and observer confidence were evaluated on 5-point scales. Radiation doses were recorded.

Results

Image quality was superior in the SD-CCTA compared to the LD-CCTA (SR 1.45±0.40; AF 1.72±0.46; vs. SR 1.83±0.48; AF 1.92±0.50; p < 0.001). Observers were more confident with SD-CCTA than with LD-CCTA (SR 1.38±0.33; AF 1.61±0.43; vs. SR 1.70±0.45; AF 1.82±0.50; p < 0.001). Radiation doses in AF were significantly higher than in the SR (LD-CCTA, 1.68±0.71 mSv; SD-CCTA, 3.72±1.95 mSv; vs. LD-CCTA, 1.3 ±0.52 mSv; SD-CCTA, 2.67±1.47 mSv; p < 0.001).

Conclusion

Using a low-dose protocol in AF, radiation exposure can be decreased by 50 % at the expense of 20 % impaired image quality. A low-dose CCTA protocol can be considered in young patients, whereas the standard-dose protocol is recommended for older patients and those suspected of having CAD.

Key Points

• Whole-heart CT allows visualization of the coronary arteries in atrial fibrillation.

• Low-dose CT decreases radiation exposure by 50%, image quality by 20%.

• Standard-dose CT seems advantageous when concomitant coronary artery disease is suspected.