Mol Imaging Biol. 2021 Nov 16. doi: 10.1007/s11307-021-01681-2. Online ahead of print.
ABSTRACT
PURPOSE: Accurate diagnosis of amyloidosis remains a significant clinical challenge and unmet need for patients. The amyloid-reactive peptide p5+14 radiolabeled with iodine-124 has been developed for the detection of amyloid by PET/CT imaging. In a first-in-human evaluation, the dosimetry and tissue distribution of 124I-p5+14 peptide in patients with systemic amyloidosis. Here in, we report the dosimetry and dynamic distribution in the first three enrolled patients with light chain-associated (AL) amyloidosis.
PROCEDURES: The radiotracer was assessed in a single-site, open-label phase 1 study (NCT03678259). The first three patients received a single intravenous infusion of 124I-p5+14 peptide (≤37 MBq). Serial PET/CT imaging was performed during the 48 h post-infusion. Dosimetry was determined as a primary endpoint for each patient and gender-averaged mean values were calculated. Pharmacokinetic parameters were estimated from whole blood radioactivity measurements and organ-based time activity data. Lastly, the biodistribution of radiotracer in major organs was assessed visually and compared to clinically appreciated organ involvement.
RESULTS: Infusion of the 124I-p5+14 was well tolerated with rapid uptake in the heart, kidneys, liver, spleen, pancreas, and lung. The gender-averaged whole-body effective radiation dose w as estimated to be 0.23 (± 0.02) mSv/MBq with elimination of the radioactivity via renal and gastrointestinal routes. The whole blood elimination t1/2 of 21.9 ± 7.6 h. Organ-based activity concentration measurements indicated that AUClast tissue:blood ratios generally correlated with the anticipated presence of amyloid. Peptide uptake was observed in 4/5 clinically suspected organs, as noted in the medical record, as well as six anatomic sites generally associated with amyloidosis in this population.
CONCLUSION: Peptide 124I-p5+14 rapidly distributes to anatomic sites consistent with the presence of amyloid in patients with systemic AL. The dosimetry estimates established in this cohort are acceptable for whole-body PET/CT imaging. Pharmacokinetic parameters are heterogeneous and consistent with uptake of the tracer in an amyloid compartment. PET/CT imaging of 124I-p5+14 may facilitate non-invasive detection of amyloid in multiple organ systems.
PMID:34786667 | DOI:10.1007/s11307-021-01681-2