Objectives/Hypothesis
To compare the hemostatic effects of commonly used concentrations of topical epinephrine in tympanoplasty.
Study Design
Prospective, randomized, controlled clinical trial.
Methods
Patients undergoing tympanoplasty were randomized to receive topical epinephrine at 1:1,000 or 1:10,000. With the investigators blinded, hemostasis was assessed with a modified Boezaart scale. Vasoconstriction was measured by laser Doppler. Blood pressure and pulse were tracked.
Results
Thirty patients, 4 to 84 years old, were studied, with 15 patients per group. Boezaart scores dropped a mean of 67% and 62% with 1:1,000 and 1:10,000, respectively (P = .44). Capillary blood flow decreased a mean of 50.4% and 50.9% with 1:1,000 and 1:10,000, respectively (P = .95). The mean change in heart rate and mean arterial pressure after topical epinephrine exposure were −4.9 and −0.73 beats per minute (P = .15), and −0.60 and −0.73 mmHg (P = .96) for 1:1,000 and 1:10,000 respectively. No adverse events occurred in either group.
Conclusions
Topical epinephrine at 1:10,000 has hemostatic efficacy comparable to 1:1,000 in tympanoplasty. Although both concentrations appear safe, use of topical epinephrine 1:10,000 should be considered over 1:1,000 to minimize the potential for adverse events.
Level of Evidence
2 Laryngoscope, 2021
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου
Σημείωση: Μόνο ένα μέλος αυτού του ιστολογίου μπορεί να αναρτήσει σχόλιο.