Impact of simethicone on bowel cleansing during colonoscopy in Chinese patients

paythelady.612 shared this article with you from Inoreader

World J Clin Cases. 2021 Apr 6;9(10):2238-2246. doi: 10.12998/wjcc.v9.i10.2238.

ABSTRACT

BACKGROUND: Four-liter polyethylene glycol (PEG) solutions are effective for bowel cleansing, but their large volume might hinder patient compliance. Due to the unique features of Asians, 4 L PEG might be a suboptimal bowel preparation in predominantly ethnically Asian countries. In view of this, a balance should be achieved between the volume and effectiveness. The ideal bowel cleansing regimen for a colonoscopy has yet to be determined in a Chinese population.

AIM: To compare the cleansing efficacy of 3 L PEG plus simethicone with 4 L PEG.

METHODS: A total of 291 patients were randomly allocated to two groups: Group 1 (n = 145) received 4 L split-dose PEG (4-P); group 2 (n = 146) received 3 L split-dose PEG plus simethicone (3-PS). Bowel-cleansing efficacy was evaluated by endoscopists using the Boston bowel preparation scale (BBPS) and the bubbles score.

RESULTS: Although there were no significant differences in the total BBPS score or the adequate rate of bowel preparation between the two groups, the BBPS score of the right-side colon was significantly higher in the 3-SP group (2.37 ± 0.54 vs 2.21 ± 0.78; P = 0.04). Moreover, the use of simethicone significantly reduced bubbles in all colon segments (P < 0.001). The mean withdrawal time was significantly shorter in the 3-PS group (8.8 ± 3.4 vs 9.6 ± 2.3; P = 0.02). Furthermore, significantly more proximal adenomas were detected in the 3-PS group (53.6% vs 45.7%; P = 0.03). In addition, the proportions of patients with nausea and bloating were significantly lower in the 3-SP group (P < 0.01 for both). More patients in the 3-PS group expressed willingness to repeat the bowel preparation (87.7% vs 76.6%, P = 0.01).

CONCLUSION: Three-liter PEG shows satisfacto ry bowel cleansing despite the decrease in dosage, and addition of simethicone with better bubble elimination and enhanced patient acceptance offers excellent potential impact on the detection of proximal adenomas in Chinese patients.

PMID:33869599 | PMC:PMC8026841 | DOI:10.12998/wjcc.v9.i10.2238