Abstract
Background
The purpose of this study was to create dental radiation maps to calculate the mean dose to individual teeth, maxilla and mandible using intensity‐modulated radiation therapy (IMRT).
Methods
Eighteen common clinical settings were chosen. Radiation plans were extracted, and each tooth was contoured at its junction with the gingiva and labeled based on the Universal/American numbering system.
Results
All patients were treated with prescribed doses of 50–70 Gy in 1.66–2 Gy/fraction. Patients receiving mean doses >50 Gy to the teeth, mandible, and maxilla included those with advanced tumors of the oral cavity and gross lymphadenopathy of level 1b.
Conclusion
We believe this to be the first study generating dosimetric maps of estimated doses to each tooth and each third of the mandible and the maxilla for common examples of head and neck cancer faced by radiation oncologists. Adoption of these dental maps may help improve clinical workflow efficiency.