Objective
Assess construct validity of a low‐cost medium‐fidelity silicone injection molded model task trainer for endoscopic sinus surgery (ESS) training.
Methods
Fellowship‐trained rhinologists, otolaryngology attendings, and otolaryngology residents at various levels of training performed sinus endoscopy and seven procedures on the model. Construct validity was evaluated by comparing novice to various levels of experienced performance using a validated checklist.
Results
Thirty‐two subjects participated in this study. Otolaryngology attendings and postgraduate year (PGY) 3 to 5 otolaryngology residents significantly outperformed PGY 1 to 2 otolaryngology residents on most tasks in the task‐specific checklist.
Conclusions
This study demonstrated the construct validity of the low‐cost medium‐fidelity ESS model.
Level of Evidence
NA. Laryngoscope, 2018
http://bit.ly/2PY3FMO
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου
Σημείωση: Μόνο ένα μέλος αυτού του ιστολογίου μπορεί να αναρτήσει σχόλιο.