Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00306932607174,00302841026182,alsfakia@gmail.com
Αναζήτηση αυτού του ιστολογίου
Πληροφορίες
Ετικέτες
Τρίτη 3 Απριλίου 2018
RAD51 foci as a functional biomarker of homologous recombination repair and PARP inhibitor resistance in germline BRCA mutated breast cancer
Induction Chemotherapy in Locally Advanced Squamous Cell Carcinoma of the Head and Neck: Role, Controversy, and Future Directions
Neo-adjuvant chemotherapy followed by chemoradiation and surgery with and without cetuximab in patients with resectable esophageal cancer: a randomized, open-label, phase III trial (SAKK 75/08)
Relationship between environmental factors, age of onset and familial history in Japanese patients with psoriasis
The Journal of Dermatology, EarlyView.
Review on applications of artificial intelligence methods for dam and reservoir-hydro-environment models
Abstract
Efficacious operation for dam and reservoir system could guarantee not only a defenselessness policy against natural hazard but also identify rule to meet the water demand. Successful operation of dam and reservoir systems to ensure optimal use of water resources could be unattainable without accurate and reliable simulation models. According to the highly stochastic nature of hydrologic parameters, developing accurate predictive model that efficiently mimic such a complex pattern is an increasing domain of research. During the last two decades, artificial intelligence (AI) techniques have been significantly utilized for attaining a robust modeling to handle different stochastic hydrological parameters. AI techniques have also shown considerable progress in finding optimal rules for reservoir operation. This review research explores the history of developing AI in reservoir inflow forecasting and prediction of evaporation from a reservoir as the major components of the reservoir simulation. In addition, critical assessment of the advantages and disadvantages of integrated AI simulation methods with optimization methods has been reported. Future research on the potential of utilizing new innovative methods based AI techniques for reservoir simulation and optimization models have also been discussed. Finally, proposal for the new mathematical procedure to accomplish the realistic evaluation of the whole optimization model performance (reliability, resilience, and vulnerability indices) has been recommended.
The role of the water footprint in the context of green marketing
Abstract
The environmental degradation, because of various factors, such as climate change, human activities, increase of population globally, etc. have brought on pressures on the fresh water supplies that vary on time and space. Consequently, economic, environmental, and social tools have emerged known as footprints, in an effort to examine and measure the needs and consequences of humanity on the Earth's life support systems and take measures towards sustainable development. Furthermore, the constantly worsening environmental conditions have resulted in the cultivation of a green culture among society stakeholders that brought on terms such as green marketing and green products. This paper deals with the water footprint (WF) concept and an effort is performed, to explore through a literature review, in which ways it can contribute to the sustainable development of water use, in the context of green marketing (GM) strategies. The approach of the analysis is based on the discrimination to the following aspects: international scale, national and subnational scale, farmers, business, and consumers, in order to track the affection of each part in water issues. The main findings of the literature review showed that the aforementioned factors are playing a key role in protecting water recourses, by the way they formulate their water use and they are interrelated and interdependent. WFs can be useful in the context of GM, by providing helpful information about direct and indirect water consumption, to every contributor factor in supply chains, to consumers, governments, and water managers.
Official control of plant protection products in Poland: detection of illegal products
Abstract
Market presence of illegal and counterfeit pesticides is now a global problem. According to data published in 2012 by the European Crop Protection Association (ECPA), illegal products represent over 10% of the global market of plant protection products. Financial benefits are the main reason for the prevalence of this practice. Counterfeit and illegal pesticides may contain substances that may pose a threat to the environment, crops, animals, and humans, inconsistent with the label and registration dossier. In Poland, action against illegal and counterfeit plant protection products is undertaken by the Main Inspectorate of Plant Health and Seed Inspection (PIORiN), the police, the prosecution, and the pesticide producers. Results of chemical analyses carried out by the Institute of Plant Protection - National Research Institute Sośnicowice Branch, Pesticide Quality Testing Laboratory (PQTL IPP-NRI Sosnicowice Branch) indicate that a majority of illegal pesticides in Poland are detected in the group of herbicides. Products from parallel trade tend to have the most irregularities. This article describes the official quality control system of plant protection products in Poland and presents the analytical methods for testing pesticides suspected of adulteration and recent test results.
Can We Perform CT of the Appendix with Less Than 1 mSv? A De-escalating Dose-simulation Study
Abstract
Objectives
To systematically explore the lowest reasonably achievable radiation dose for appendiceal CT using an iterative reconstruction (IR) in young adults.
Methods
We prospectively included 30 patients who underwent 2.0-mSv CT for suspected appendicitis. From the helical projection data, 1.5-, 1.0- and 0.5-mSv CTs were generated using a low-dose simulation tool and the knowledge-based IR. We performed step-wise non-inferiority tests sequentially comparing 2.0-mSv CT with each of 1.5-, 1.0- and 0.5-mSv CT, with a predetermined non-inferiority margin of 0.06. The primary end point was the pooled area under the receiver-operating-characteristic curve (AUC) for three abdominal and three non-abdominal radiologists.
Results
For the abdominal radiologists, the non-inferiorities of 1.5-, 1.0- and 0.5-mSv CT to 2.0-mSv CT were sequentially accepted [pooled AUC difference: 2.0 vs. 0.5 mSv, 0.017 (95% CI: -0.016, 0.050)]. For the non-abdominal radiologists, the non-inferiorities of 1.5- and 1.0-mSv CT were accepted; however, the non-inferiority of 0.5-mSv CT could not be proved [pooled AUC difference: 2.0 vs. 1.0 mSv, -0.017 (-0.070, 0.035) and 2.0 vs. 0.5 mSv, 0.045 (-0.071, 0.161)].
Conclusion
The 1.0-mSv appendiceal CT was non-inferior to 2.0-mSv CT in terms of diagnostic performance for both abdominal and non-abdominal radiologists; 0.5-mSv appendiceal CT was non-inferior only for abdominal radiologists.
Key points
• For both abdominal and non-abdominal radiologists, 1.0-mSv appendiceal CT could be feasible.
• The 0.5-mSv CT was non-inferior to 2.0-mSv CT only for expert abdominal radiologists.
• Reader experience is an important factor affecting diagnostic impairment by low-dose CT.
Cervical ultrasonography has no additional value over negative 18 F-FDG PET/CT scans for diagnosing cervical lymph node metastases in patients with oesophageal cancer
Abstract
Objectives
To investigate the additional value of cervical ultrasonography over 18F-FDG PET/CT for diagnosing cervical lymph node metastases in patients with newly diagnosed oesophageal cancer.
Methods
Between January 2013 and January 2016, 163 patients with newly diagnosed oesophageal cancer underwent both cervical ultrasonography and 18F-FDG PET/CT at a tertiary referral centre in the Netherlands. Retrospective clinical data analysis was performed to assess the diagnostic value of cervical ultrasonography and 18F-FDG PET/CT for the detection of cervical lymph node metastases. Fine needle aspiration or clinical follow-up was used as reference standard.
Results
The overall incidence of patients with cervical lymph node metastases was 14%. The sensitivity of 18F-FDG PET/CT to detect cervical lymph node metastases was 82% (95% CI 59–94%) and specificity was 91% (95% CI 85–95%). The sensitivity and specificity of cervical ultrasonography were 73% (95% CI 50–88%) and 84% (95% CI 77–90%), respectively. In patients with a negative 18F-FDG PET/CT, 12 of 133 (9%) patients had suspicious nodes on cervical ultrasonography. In all these 12 patients the nodes were confirmed benign.
Conclusions
Cervical ultrasonography has no additional diagnostic value to a negative integrated 18F-FDG PET/CT for the detection of cervical lymph node metastases in patients with newly diagnosed oesophageal cancer.
Key Points
• Cervical ultrasonography has no value over PET/CT in evaluating cervical node metastases.
• PET/CT provides greater diagnostic confidence compared to cervical ultrasonography.
• Cervical ultrasonography during standard diagnostic work-up may be considered unnecessary.
• Cervical lesions on PET/CT require cytopathological confirmation by FNA.
Round-the-clock performance of coronary CT angiography for suspected acute coronary syndrome: Results from the BEACON trial
Abstract
Objective
To assess the image quality of coronary CT angiography (CCTA) for suspected acute coronary syndrome (ACS) outside office hours.
Methods
Patients with symptoms suggestive of an ACS underwent CCTA at the emergency department 24 hours, 7 days a week. A total of 118 patients, of whom 89 (75 %) presented during office hours (weekdays between 07:00 and 17:00) and 29 (25 %) outside office hours (weekdays between 17:00 and 07:00, weekends and holidays) underwent CCTA. Image quality was evaluated per coronary segment by two experienced readers and graded on an ordinal scale ranging from 1 to 3.
Results
There were no significant differences in acquisition parameters, beta-blocker administration or heart rate between patients presenting during office hours and outside office hours. The median quality score per patient was 30.5 [interquartile range 26.0–33.5] for patients presenting during office hours in comparison to 27.5 [19.75–32.0] for patients presenting outside office hours (p=0.043). The number of non-evaluable segments was lower for patients presenting during office hours (0 [0–1.0] vs. 1.0 [0–4.0], p=0.009).
Conclusion
Image quality of CCTA outside office hours in the diagnosis of suspected ACS is diminished.
Key Points
• Quality scores were higher for coronary-CTA during office hours.
• There were no differences in acquisition parameters.
• There was a non-significant trend towards higher heart rates outside office hours.
• Coronary-CTA on the ED requires state-of-the-art scanner technology and sufficiently trained staff.
• Coronary-CTA on the ED needs preparation time and optimisation of the procedure.
The impact of injector-based contrast agent administration in time-resolved MRA
Abstract
Objectives
Time-resolved contrast-enhanced MR angiography (4D-MRA), which allows the simultaneous visualization of the vasculature and blood-flow dynamics, is widely used in clinical routine. In this study, the impact of two different contrast agent injection methods on 4D-MRA was examined in a controlled, standardized setting in an animal model.
Methods
Six anesthetized Goettingen minipigs underwent two identical 4D-MRA examinations at 1.5 T in a single session. The contrast agent (0.1 mmol/kg body weight gadobutrol, followed by 20 ml saline) was injected using either manual injection or an automated injection system. A quantitative comparison of vascular signal enhancement and quantitative renal perfusion analyses were performed.
Results
Analysis of signal enhancement revealed higher peak enhancements and shorter time to peak intervals for the automated injection. Significantly different bolus shapes were found: automated injection resulted in a compact first-pass bolus shape clearly separated from the recirculation while manual injection resulted in a disrupted first-pass bolus with two peaks. In the quantitative perfusion analyses, statistically significant differences in plasma flow values were found between the injection methods.
Conclusions
The results of both qualitative and quantitative 4D-MRA depend on the contrast agent injection method, with automated injection providing more defined bolus shapes and more standardized examination protocols.
Key points
• Automated and manual contrast agent injection result in different bolus shapes in 4D-MRA.
• Manual injection results in an undefined and interrupted bolus with two peaks.
• Automated injection provides more defined bolus shapes.
• Automated injection can lead to more standardized examination protocols.
Evaluation of an adaptive detector collimation for prospectively ECG-triggered coronary CT angiography with third-generation dual-source CT
Abstract
Objectives
To investigate the impact of an adaptive detector collimation on the dose parameters and accurateness of scan length adaption at prospectively ECG-triggered sequential cardiac CT with a wide-detector third-generation dual-source CT.
Methods
Ideal scan lengths for human hearts were retrospectively derived from 103 triple-rule-out examinations. These measures were entered into the new scanner operated in prospectively ECG-triggered sequential cardiac scan mode with three different detector settings: (1) adaptive collimation, (2) fixed 64 × 0.6-mm collimation, and (3) fixed 96 × 0.6-mm collimation. Differences in effective scan length and deviation from the ideal scan length and dose parameters (CTDIvol, DLP) were documented.
Results
The ideal cardiac scan length could be matched by the adaptive collimation in every case while the mean scanned length was longer by 15.4% with the 64 × 0.6 mm and by 27.2% with the fixed 96 × 0.6-mm collimation. While the DLP was almost identical between the adaptive and the 64 × 0.6-mm collimation (83 vs. 89 mGycm at 120 kV), it was 62.7% higher with the 96 × 0.6-mm collimation (135 mGycm), p < 0.001.
Conclusion
The adaptive detector collimation for prospectively ECG-triggered sequential acquisition allows for adjusting the scan length as accurate as this can only be achieved with a spiral acquisition. This technique allows keeping patient exposure low where patient dose would significantly increase with the traditional step-and-shoot mode.
Key points
• Adaptive detector collimation allows keeping patient exposure low in cardiac CT.
• With novel detectors the desired scan length can be accurately matched.
• Differences in detector settings may cause 62.7% of excessive dose.
-
A Case of Diprosopus Tetraophthalmos: Ocular Findings and Surgical Treatment of Exposure KeratopathyDiprosopus is a rare variation of conjoined twinning. In this report, ophthalmic findings in an infant with diprosopus tetraophthalmos are p...